LED Lensed Industrial Retrofit Kit

    Part of the FormFocus product line, the FFRP is a custom fit retrofit kit designed for existing 4-foot or 8-foot industrial-style louvered luminaires. Specifications of the existing fixture is required to ensure proper fit. A new industrial luminaire with a similar appearance, the FFLP, is also available (view FFLP product page here). The FFRP's lift and shift design allows for quick and easy installation in a matter of just a few minutes. The frosted diffuser is optimized to balance efficiency and aesthetics. The tray is precision brake formed from cold rolled steel, with a matte white finish. Every FFRP is assembled in the USA - in our Henderson, NC facility.
  • Applications: Custom fit for 4-foot or 4-foot industrial-style louvered luminaires. Specifications of existing fixture required to ensure proper fit.
  • Lumen Output: From about 2,500 lm up to nearly 17,000
  • Max Lumens Per Watt: 157.4
  • Size Options: 4-foot, 8-foot
  • Predicted L70 Lifetime: Up to 189,000 hours (calculated)
  • Warranty: 5 year limited system warranty
  • Re-BoardABILITY: Every FFRP is upgradeable. Boards and drivers can easily be swapped out for upgrade in a matter of minutes. Learn more about Re-Boardability here.
  • Certifications: UL 1598 listed for US and Canada, suitable for damp locations
  • Assembled in the USA: Each FFRP is assembled at our facility in Henderson, NC. BAA compliant options are available
Click to enlarge

FFRP-4JPG FFRP-4JPG
FFRP 4-footer
FFRP-4greenJPG FFRP-4greenJPG
FFRP 4-footer, existing housing in green
FFRP-3JPG FFRP-3JPG
FFRP 4-footer
FFRP-3greenJPG FFRP-3greenJPG
FFRP 4-footer, existing housing in green
FFRP-2greenJPG FFRP-2greenJPG
FFRP 4-footer, existing housing in green
FFRP-2 FFRP-2
FFRP 4-footer
FFRP-1JPG FFRP-1JPG
FFRP 4-footer
FFRP-1greenJPG FFRP-1greenJPG
FFRP 4-footer, existing housing in green
FFRP0215-4 FFRP0215-4
FFRP 8-footer
FFRP0215-4 green FFRP0215-4 green
FFRP 8-footer, existing housing in green
FFRP0215-3 FFRP0215-3
FFRP 8-footer
FFRP0215-3 green FFRP0215-3 green
FFRP 8-footer, existing housing in green
FFRP0215-2 FFRP0215-2
FFRP 8-footer
FFRP0215-2 green FFRP0215-2 green
FFRP 8-footer, existing housing in green
FFRP0215-1 FFRP0215-1
FFRP 8-footer
FFRP0215-1 green FFRP0215-1 green
FFRP 8-footer, existing housing in green
Click to download
FFRP 4-footer
FFRP 8-footer
cULus, AiA
Note: Table scrolls horizontally
Catalog #
SizeLumensWattsLPWCRI / Color TempVoltages AvailableWarrantyPredicted L70 Lifetime
FFR P 4 VL UV FA 8304-foot2,52318140.280 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VL UV FA 8354-foot2,56518142.580 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VL UV FA 8404-foot2,65018147.280 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VL UV FA 8504-foot2,73018151.780 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW UV FA 8304-foot3,80529131.280 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW UV FA 8354-foot3,86929133.480 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW UV FA 8404-foot3,99729137.880 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW UV FA 8504-foot4,1172914280 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD UV FA 8304-foot4,3193412780 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD UV FA 8354-foot4,39234129.280 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD UV FA 8404-foot4,53734133.480 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD UV FA 8504-foot4,67334137.480 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI UV FA 8304-foot4,95839127.180 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI UV FA 8354-foot5,04239129.380 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI UV FA 8404-foot5,20839133.580 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI UV FA 8504-foot5,36539137.680 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH UV FA 8304-foot5,84648121.880 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH UV FA 8354-foot5,94548123.980 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH UV FA 8404-foot6,14148127.980 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH UV FA 8504-foot6,32548131.880 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH UV FA 8304-foot7,76063123.280 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH UV FA 8354-foot7,89063125.280 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH UV FA 8404-foot8,15163129.480 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH UV FA 8504-foot8,39563133.380 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VL UV FA 8308-foot5,09135145.580 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VL UV FA 8358-foot5,17635147.980 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VL UV FA 8408-foot5,34835152.880 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VL UV FA 8508-foot5,50835157.480 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW UV FA 8308-foot7,72157135.580 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW UV FA 8358-foot7,85157137.780 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW UV FA 8408-foot8,11057142.380 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW UV FA 8508-foot8,35457146.680 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD UV FA 8308-foot8,67065133.480 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD UV FA 8358-foot8,81665135.680 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD UV FA 8408-foot9,10765140.180 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD UV FA 8508-foot9,38165144.380 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI UV FA 8308-foot9,6187413080 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI UV FA 8358-foot9,77974132.180 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI UV FA 8408-foot10,10274136.580 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI UV FA 8508-foot10,40674140.680 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH UV FA 8308-foot11,47486133.480 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH UV FA 8358-foot11,66786135.780 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH UV FA 8408-foot12,05386140.280 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH UV FA 8508-foot12,41486144.380 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH UV FA 8308-foot15,706128122.780 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH UV FA 8358-foot15,970128124.880 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH UV FA 8408-foot16,498128128.980 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH UV FA 8508-foot16,993128132.880 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW HE UV FA 8304-foot3,75627139.180 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW HE UV FA 8354-foot3,81927141.480 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW HE UV FA 8404-foot3,94527146.180 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 LW HE UV FA 8504-foot4,06327150.580 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD HE UV FA 8304-foot4,36732136.580 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD HE UV FA 8354-foot4,44032138.880 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD HE UV FA 8404-foot4,58732143.380 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 MD HE UV FA 8504-foot4,72532147.780 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI HE UV FA 8304-foot4,84036134.480 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI HE UV FA 8354-foot4,92136136.780 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI HE UV FA 8404-foot5,08436141.280 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 HI HE UV FA 8504-foot5,23636145.480 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH HE UV FA 8304-foot5,79543134.880 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH HE UV FA 8354-foot5,8924313780 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH HE UV FA 8404-foot6,08743141.680 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 VH HE UV FA 8504-foot6,27043145.880 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH HE UV FA 8304-foot7,62460127.180 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH HE UV FA 8354-foot7,75260129.280 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH HE UV FA 8404-foot8,00960133.580 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 4 SH HE UV FA 8504-foot8,24960137.580 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW HE UV FA 8308-foot7,72654143.180 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW HE UV FA 8358-foot7,85654145.580 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW HE UV FA 8408-foot8,11654150.380 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 LW HE UV FA 8508-foot8,35954154.880 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD HE UV FA 8308-foot8,48660141.480 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD HE UV FA 8358-foot8,62960143.880 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD HE UV FA 8408-foot8,91460148.680 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 MD HE UV FA 8508-foot9,1826015380 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI HE UV FA 8308-foot9,82970140.480 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI HE UV FA 8358-foot9,99470142.880 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI HE UV FA 8408-foot10,32470147.580 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 HI HE UV FA 8508-foot10,63470151.980 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH HE UV FA 8308-foot11,72586136.380 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH HE UV FA 8358-foot11,92286138.680 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH HE UV FA 8408-foot12,31686143.280 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 VH HE UV FA 8508-foot12,68686147.580 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH HE UV FA 8308-foot15,426120128.680 CRI / 3000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH HE UV FA 8358-foot15,685120130.780 CRI / 3500K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH HE UV FA 8408-foot16,20312013580 CRI / 4000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
FFR P 8 SH HE UV FA 8508-foot16,689120139.180 CRI / 5000K120-277V, 347V5 yearsUp to 189,000 hrs (calculated)
Catalog #
Equivalency*
FFR P 4 VL UV FA 8301L F32 T8, NBF
FFR P 4 VL UV FA 8351L F32 T8, NBF
FFR P 4 VL UV FA 8401L F32 T8, NBF
FFR P 4 VL UV FA 8501L F32 T8, NBF
FFR P 4 LW UV FA 8302L F32 T8, NBF
FFR P 4 LW UV FA 8352L F32 T8, NBF
FFR P 4 LW UV FA 8402L F32 T8, NBF
FFR P 4 LW UV FA 8502L F32 T8, NBF
FFR P 4 MD UV FA 8302L F32 T8, NBF
FFR P 4 MD UV FA 8352L F32 T8, NBF
FFR P 4 MD UV FA 8402L F32 T8, NBF
FFR P 4 MD UV FA 8502L F32 T8, NBF
FFR P 4 HI UV FA 8302L F32 T8, HBF
FFR P 4 HI UV FA 8352L F32 T8, HBF
FFR P 4 HI UV FA 8402L F32 T8, HBF
FFR P 4 HI UV FA 8502L F32 T8, HBF
FFR P 4 VH UV FA 8303L F32 T8, NBF
FFR P 4 VH UV FA 8353L F32 T8, NBF
FFR P 4 VH UV FA 8403L F32 T8, NBF
FFR P 4 VH UV FA 8503L F32 T8, NBF
FFR P 4 SH UV FA 8302L F54 T5HO
FFR P 4 SH UV FA 8352L F54 T5HO
FFR P 4 SH UV FA 8402L F54 T5HO
FFR P 4 SH UV FA 8502L F54 T5HO
FFR P 8 VL UV FA 8302L F32 T8, HBF
FFR P 8 VL UV FA 8352L F32 T8, HBF
FFR P 8 VL UV FA 8402L F32 T8, HBF
FFR P 8 VL UV FA 8502L F32 T8, HBF
FFR P 8 LW UV FA 8304L F32 T8, NBF
FFR P 8 LW UV FA 8354L F32 T8, NBF
FFR P 8 LW UV FA 8404L F32 T8, NBF
FFR P 8 LW UV FA 8504L F32 T8, NBF
FFR P 8 MD UV FA 8304L F32 T8, NBF
FFR P 8 MD UV FA 8354L F32 T8, NBF
FFR P 8 MD UV FA 8404L F32 T8, NBF
FFR P 8 MD UV FA 8504L F32 T8, NBF
FFR P 8 HI UV FA 8302L F96 T8, NBF
FFR P 8 HI UV FA 8352L F96 T8, NBF
FFR P 8 HI UV FA 8402L F96 T8, NBF
FFR P 8 HI UV FA 8502L F96 T8, NBF
FFR P 8 VH UV FA 8302L F96 T8HO, NBF
FFR P 8 VH UV FA 8352L F96 T8HO, NBF
FFR P 8 VH UV FA 8402L F96 T8HO, NBF
FFR P 8 VH UV FA 8502L F96 T8HO, NBF
FFR P 8 SH UV FA 8304L F54 T5HO
FFR P 8 SH UV FA 8354L F54 T5HO
FFR P 8 SH UV FA 8404L F54 T5HO
FFR P 8 SH UV FA 8504L F54 T5HO
FFR P 4 LW HE UV FA 8302L F32 T8, NBF
FFR P 4 LW HE UV FA 8352L F32 T8, NBF
FFR P 4 LW HE UV FA 8402L F32 T8, NBF
FFR P 4 LW HE UV FA 8502L F32 T8, NBF
FFR P 4 MD HE UV FA 8302L F32 T8, NBF
FFR P 4 MD HE UV FA 8352L F32 T8, NBF
FFR P 4 MD HE UV FA 8402L F32 T8, NBF
FFR P 4 MD HE UV FA 8502L F32 T8, NBF
FFR P 4 HI HE UV FA 8302L F32 T8, HBF
FFR P 4 HI HE UV FA 8352L F32 T8, HBF
FFR P 4 HI HE UV FA 8402L F32 T8, HBF
FFR P 4 HI HE UV FA 8502L F32 T8, HBF
FFR P 4 VH HE UV FA 8303L F32 T8, NBF
FFR P 4 VH HE UV FA 8353L F32 T8, NBF
FFR P 4 VH HE UV FA 8403L F32 T8, NBF
FFR P 4 VH HE UV FA 8503L F32 T8, NBF
FFR P 4 SH HE UV FA 8302L F54 T5HO
FFR P 4 SH HE UV FA 8352L F54 T5HO
FFR P 4 SH HE UV FA 8402L F54 T5HO
FFR P 4 SH HE UV FA 8502L F54 T5HO
FFR P 8 LW HE UV FA 8304L F32 T8, NBF
FFR P 8 LW HE UV FA 8354L F32 T8, NBF
FFR P 8 LW HE UV FA 8404L F32 T8, NBF
FFR P 8 LW HE UV FA 8504L F32 T8, NBF
FFR P 8 MD HE UV FA 8304L F32 T8, NBF
FFR P 8 MD HE UV FA 8354L F32 T8, NBF
FFR P 8 MD HE UV FA 8404L F32 T8, NBF
FFR P 8 MD HE UV FA 8504L F32 T8, NBF
FFR P 8 HI HE UV FA 8302L F96 T8, NBF
FFR P 8 HI HE UV FA 8352L F96 T8, NBF
FFR P 8 HI HE UV FA 8402L F96 T8, NBF
FFR P 8 HI HE UV FA 8502L F96 T8, NBF
FFR P 8 VH HE UV FA 8302L F96 T8HO, NBF
FFR P 8 VH HE UV FA 8352L F96 T8HO, NBF
FFR P 8 VH HE UV FA 8402L F96 T8HO, NBF
FFR P 8 VH HE UV FA 8502L F96 T8HO, NBF
FFR P 8 SH HE UV FA 8304L F54 T5HO
FFR P 8 SH HE UV FA 8354L F54 T5HO
FFR P 8 SH HE UV FA 8404L F54 T5HO
FFR P 8 SH HE UV FA 8504L F54 T5HO
*NOTE: Fixture equivalencies are estimates only and should be confirmed by photometric analysis or sample install to ensure adequate light levels are achieved.
Catalog #
ImageSpec Sheet
FFR P 4 VL UV FA 830View Download
FFR P 4 VL UV FA 835View Download
FFR P 4 VL UV FA 840View Download
FFR P 4 VL UV FA 850View Download
FFR P 4 LW UV FA 830View Download
FFR P 4 LW UV FA 835View Download
FFR P 4 LW UV FA 840View Download
FFR P 4 LW UV FA 850View Download
FFR P 4 MD UV FA 830View Download
FFR P 4 MD UV FA 835View Download
FFR P 4 MD UV FA 840View Download
FFR P 4 MD UV FA 850View Download
FFR P 4 HI UV FA 830View Download
FFR P 4 HI UV FA 835View Download
FFR P 4 HI UV FA 840View Download
FFR P 4 HI UV FA 850View Download
FFR P 4 VH UV FA 830View Download
FFR P 4 VH UV FA 835View Download
FFR P 4 VH UV FA 840View Download
FFR P 4 VH UV FA 850View Download
FFR P 4 SH UV FA 830View Download
FFR P 4 SH UV FA 835View Download
FFR P 4 SH UV FA 840View Download
FFR P 4 SH UV FA 850View Download
FFR P 8 VL UV FA 830View Download
FFR P 8 VL UV FA 835View Download
FFR P 8 VL UV FA 840View Download
FFR P 8 VL UV FA 850View Download
FFR P 8 LW UV FA 830View Download
FFR P 8 LW UV FA 835View Download
FFR P 8 LW UV FA 840View Download
FFR P 8 LW UV FA 850View Download
FFR P 8 MD UV FA 830View Download
FFR P 8 MD UV FA 835View Download
FFR P 8 MD UV FA 840View Download
FFR P 8 MD UV FA 850View Download
FFR P 8 HI UV FA 830View Download
FFR P 8 HI UV FA 835View Download
FFR P 8 HI UV FA 840View Download
FFR P 8 HI UV FA 850View Download
FFR P 8 VH UV FA 830View Download
FFR P 8 VH UV FA 835View Download
FFR P 8 VH UV FA 840View Download
FFR P 8 VH UV FA 850View Download
FFR P 8 SH UV FA 830View Download
FFR P 8 SH UV FA 835View Download
FFR P 8 SH UV FA 840View Download
FFR P 8 SH UV FA 850View Download
FFR P 4 LW HE UV FA 830View Download
FFR P 4 LW HE UV FA 835View Download
FFR P 4 LW HE UV FA 840View Download
FFR P 4 LW HE UV FA 850View Download
FFR P 4 MD HE UV FA 830View Download
FFR P 4 MD HE UV FA 835View Download
FFR P 4 MD HE UV FA 840View Download
FFR P 4 MD HE UV FA 850View Download
FFR P 4 HI HE UV FA 830View Download
FFR P 4 HI HE UV FA 835View Download
FFR P 4 HI HE UV FA 840View Download
FFR P 4 HI HE UV FA 850View Download
FFR P 4 VH HE UV FA 830View Download
FFR P 4 VH HE UV FA 835View Download
FFR P 4 VH HE UV FA 840View Download
FFR P 4 VH HE UV FA 850View Download
FFR P 4 SH HE UV FA 830View Download
FFR P 4 SH HE UV FA 835View Download
FFR P 4 SH HE UV FA 840View Download
FFR P 4 SH HE UV FA 850View Download
FFR P 8 LW HE UV FA 830View Download
FFR P 8 LW HE UV FA 835View Download
FFR P 8 LW HE UV FA 840View Download
FFR P 8 LW HE UV FA 850View Download
FFR P 8 MD HE UV FA 830View Download
FFR P 8 MD HE UV FA 835View Download
FFR P 8 MD HE UV FA 840View Download
FFR P 8 MD HE UV FA 850View Download
FFR P 8 HI HE UV FA 830View Download
FFR P 8 HI HE UV FA 835View Download
FFR P 8 HI HE UV FA 840View Download
FFR P 8 HI HE UV FA 850View Download
FFR P 8 VH HE UV FA 830View Download
FFR P 8 VH HE UV FA 835View Download
FFR P 8 VH HE UV FA 840View Download
FFR P 8 VH HE UV FA 850View Download
FFR P 8 SH HE UV FA 830View Download
FFR P 8 SH HE UV FA 835View Download
FFR P 8 SH HE UV FA 840View Download
FFR P 8 SH HE UV FA 850View Download
FFRP8ftPNGweb

Lift and shift

    The FFRP utilizes a "lift and shift" design concept, which allows it to quickly and easily be installed in the field. The kit ships with the LED drivers and boards installed on the tray. With the original lamps and ballasts removed, the retrofit unit is hung on one side of the existing housing. Safety tethers on both ends of the kit (two for the 4-footer, four for the 8-footer) are screwed into the existing housing for added security. The installer wires the driver to the existing power via a quick-disconnect before swinging the kit around to attach the other side. The whole process takes just a few minutes.
FFRP8ftPNGweb

Lift and shift

    The FFRP utilizes a "lift and shift" design concept, which allows it to quickly and easily be installed in the field. The kit ships with the LED drivers and boards installed on the tray. With the original lamps and ballasts removed, the retrofit unit is hung on one side of the existing housing. Safety tethers on both ends of the kit (two for the 4-footer, four for the 8-footer) are screwed into the existing housing for added security. The installer wires the driver to the existing power via a quick-disconnect before swinging the kit around to attach the other side. The whole process takes just a few minutes.

Follow us on social media: