LED 4' Vaportight High Bay

Durable materials and craftsmanship allows the WVL4 to withstand some of the harshest environments. The UL 5VA fiberglass housing will not melt or burn. Multiple hanging options available, including surface, chain and aircraft cable, for easy installation (more info below). Impact resistant acrylic and UV stabilized polycarbonate lenses are available as well. The WVL4 is made in the USA - engineered and manufactured at our facility in Henderson, NC.

  • Applications: Suitable for most industrial, retail and recreational low bay and high bay applications - warehouse, manufacturing facility, food processing, freezer, gymnasium
  • Lumen Output: From 16,000 lm - 32,000 lm
  • Max Lumens Per Watt: 148
  • Size Options: 4-foot. 2-footer available as WVL2 (click here for WVL2 page)
  • Predicted L70 Lifetime: > 100,000 hours (calculated)
  • Warranty: 5 year limited system warranty
  • Certifications: UL 1598 listed for US and Canada, suitable for wet locations. DesignLights Consortium qualified on specific configurations. Other certifications: IP65, IP66, IP67, NEMA 4X, NSF, PSI 1500, RoHS
  • Made in America: Engineered and made in the USA. Each WVL4 is manufactured in our Henderson, NC facility
MountingOptionsUpdated3
    The WVL4 features multiple hanging options, including the Flexible Ceiling Mount (FCM), the Rigid Mounting Beam in both stainless steel and zinc-plated variations (RBS and RBZ), and the V-hook (VHK) for chain or cable mount.
https://www.lumenfocus.com/wp-content/uploads/2017/12/WVL4-frosted-lens-stroke-lightened-1217-for-WP.jpg
WVL4 with frosted lens
https://www.lumenfocus.com/wp-content/uploads/2017/04/WVL4-frosted-lens3JPG.jpg
WVL4 with frosted lens
https://www.lumenfocus.com/wp-content/uploads/2017/04/WVL2-clear-lens-WP-readyJPG.jpg
WVL4 with clear acrylic lens
https://www.lumenfocus.com/wp-content/uploads/2017/04/WVL-Frosted-lens4jpg.jpg
WVL4 with frosted lens
https://www.lumenfocus.com/wp-content/uploads/2017/04/WVL2-clear-lens-2-WP-readyJPG.jpg
WVL4 with clear acrylic lens
https://www.lumenfocus.com/wp-content/uploads/2017/04/WVL-Frosted-lens2jpg.jpg
WVL4 with frosted lens
https://www.lumenfocus.com/wp-content/uploads/2017/04/WVL4-clear-lens-WPready-041817.jpg
WVL4 with clear acrylic lens
https://www.lumenfocus.com/wp-content/uploads/2017/03/WVL4-WP-update-031717.jpg
WVL4 with frosted lens

WVL4 Performance Chart

Catalog #
SizeLumensWattsLPWCRI / Color TempShieldingVoltages AvailableDLC ListedWarrantyPredicted L70 LifetimeEquivalency*
WVL 4 LW UV FA 835
Image
4-foot16,534122135.980 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 LW UV FA 840
Image
4-foot17,045122140.180 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 LW UV FA 850
Photometry Files | Image
4-foot17,557122144.380 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV FA 835
Photometry Files | Image
4-foot20,051156128.980 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV FA 840
Image
4-foot20,671156132.980 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV FA 850
Photometry Files | Image
4-foot21,291156136.980 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 HI UV FA 835
Image
4-foot23,196168138.180 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 HI UV FA 840
Image
4-foot23,913168142.380 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 HI UV FA 850
Photometry Files | Image
4-foot24,630168146.680 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 SH UV FA 835
Image
4-foot30,326227133.780 CRI / 3500KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 SH UV FA 840
Image
4-foot31,264227137.880 CRI / 4000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 SH UV FA 850
Photometry Files | Image
4-foot32,202227141.980 CRI / 5000KFrosted acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 LW UV CA 835
Image
4-foot16,79012213880 CRI / 3500KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 LW UV CA 840
Image
4-foot17,309122142.280 CRI / 4000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 LW UV CA 850
Photometry Files | Image
4-foot17,828122146.580 CRI / 5000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV CA 835
Photometry Files | Image
4-foot20,371156130.980 CRI / 3500KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV CA 840
Image
4-foot21,00115613580 CRI / 4000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV CA 850
Photometry Files | Image
4-foot21,63115613980 CRI / 5000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 HI UV CA 835
Image
4-foot23,554168140.280 CRI / 3500KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 HI UV CA 840
Image
4-foot24,283168144.580 CRI / 4000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 HI UV CA 850
Photometry Files | Image
4-foot25,011168148.980 CRI / 5000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 SH UV CA 835
Image
4-foot30,795227135.780 CRI / 3500KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 SH UV CA 840
Image
4-foot31,748227139.980 CRI / 4000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 SH UV CA 850
Photometry Files | Image
4-foot32,700227144.180 CRI / 5000KClear acrylic120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 LW UV CP 835
Image
4-foot16,487122135.580 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 LW UV CP 840
Image
4-foot16,997122139.780 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 LW UV CP 850
Photometry Files | Image
4-foot17,507122143.980 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 6-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV CP 835
Photometry Files | Image
4-foot20,004156128.680 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV CP 840
Image
4-foot20,623156132.580 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 MD UV CP 850
Photometry Files | Image
4-foot21,242156136.580 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 7-lamp F32 T8 with HBF, 4-lamp T5HO, or 400W MH in a 4-foot vaportight
WVL 4 HI UV CP 835
Image
4-foot23,130168137.780 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 HI UV CP 840
Image
4-foot23,846168141.980 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 HI UV CP 850
Photometry Files | Image
4-foot24,561168146.280 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp F32 T8 with HBF, 5-lamp T5HO, or 400W PSMH in a 4-foot vaportight
WVL 4 SH UV CP 835
Photometry Files | Image
4-foot30,241227133.380 CRI / 3500KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 SH UV CP 840
Image
4-foot31,176227137.480 CRI / 4000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
WVL 4 SH UV CP 850
Photometry Files | Image
4-foot32,111227141.580 CRI / 5000KClear polycarbonate120-277V, 347V, 480VYes5 years>100,000 hrs (calculated)Replaces 8-lamp T5HO, or 400W HPS in a 4-foot vaportight
*NOTE: Fixture equivalencies are estimates only and should be confirmed by photometric analysis or sample install to ensure adequate light levels are achieved.